Effect of Polarity Reversal on the Partial Discharge Phenomena
2020
In the field of High Voltage Direct Current (HVDC) transmission, the space charge accumulation phenomenon and the Partial Discharges (PD) phenomena are considered the main causes of dielectric ageing. During the years, the degradation effect of both phenomena under constant DC stress has been widely studied by several researchers. In case of polarity reversal, typically carried out to control bi-directional power flow between interconnected High Voltage transmission systems, the space charge movement may not synchronously follow the electric field polarity. This could make the moment of reversing polarity a very critical one, where space charge injected during preceding polarity produces hi…
Review of the PEA Method for Space Charge Measurements on HVDC Cables and Mini-Cables
2019
This review takes into account articles and standards published in recent years concerning the application of the Pulsed Electro Acoustic (PEA) method for space charge measurement on High Voltage Direct Current (HVDC) cables and mini-cables. Since the 80s, the PEA method has been implemented for space charge measurements on flat specimens in order to investigate space charge phenomena and to evaluate the ageing of dielectrics. In recent years, this technique has been adapted to cylindrical geometry. Several studies and experiments have been carried out on the use of the PEA method for full size cables and HVDC cable models. The experiments have been conducted using different arrangements of…
The effect of the axial heat transfer on space charge accumulation phenomena in HVDC cables
2020
To date, it has been widespread accepted that the presence of space charge within the dielectric of high voltage direct current (HVDC) cables is one of the most relevant issues that limits the growing diffusion of this technology and its use at higher voltages. One of the reasons that leads to the establishment of space charge within the insulation of cables is the temperature dependence of its conductivity. Many researchers have demonstrated that high temperature drop over the insulation layer can lead to the reversal of the electric field profile. In certain conditions, this can over-stress the insulation during polarity reversal (PR) and transient over voltages (TOV) events accelerating …
Energy Storage by using HVDC Power Cables
2018
The development of HVDC (high voltage direct current) systems closely follow the growth of global energy requirements. In particular, HVDC cables are conveniently used for the interconnection of geographical areas which need a low environmental impact and/or when submarines interconnections have to be built up. The paper investigates the stored energy value in an HVDC cable during its normal duty and if it is possible to take advantage of this energy when the cable is disconnected for some reason. In particular, the idea is to store the cable energy, which would be dissipated uselessly, by using a dedicated system and then reuse it when favorable conditions hold, e.g a convenient economic s…
Primary Frequency Control in the Power System of Continental Europe including the Dynamics of the HVDC Link France-Great Britain
2020
The paper presents a study of primary frequency control within the power system of Continental Europe (CE) including the dynamics of the high voltage direct current (HVDC) link between France and Great Britain (GB). The large-scale dynamic model of the CE system originally provided by ENTSO-E is extended with a more detailed representation of the whole HVDC interconnection. The dynamics of the GB synchronous area is also considered in the analysis, implementing a system equivalent suitable for primary frequency control studies. The opportunity of frequency containment reserve exchange between the two areas through the link is also investigated, considering supplementary frequency controls w…
Effect of Acoustic Wave Reflections on Space Charge Measurements with PEA Method
2018
The Pulsed Electro-Acoustic (PEA) method is the most used technique for space charge detection in solid dielectrics. The methodology is largely employed in the field of High Voltage Direct Current (HVDC) transmission and is based on the detection of acoustic waves generated by charges vibration. One of the most common problems arising during the detection is the presence of multiple reflections taking place due to the presence of means discontinuity in the different PEA cell components. This reflection phenomenon, if not well taken into account, could cause incorrect interpretation of the PEA output signal. It is easy to understand that a simulation model is a basic tool to understand the w…